When you examine the properties of a floor you'll find Perimeter. Somebody decided perimeter shouldn't be available to tags so we can't tag a floor but we can see it in schedule (no, can't tag it in 2014 either).

If you alter a floor sketch to define an opening for something like for a stair or a mechanical chase, it alters the perimeter calculation. If you use either a Shaft Opening or Opening by Face it doesn't alter the perimeter value. Floor A is untouched, B is altered within the sketch and C has two openings one of each type. You'll see in the schedule that perimeter is not altered except where the floor sketch is changed to create the opening.


The moral of the story? If you'd like to be able to use the floor slab perimeter value then don't edit the floor sketch to create openings.